PRIMAC UV-01 and UV-01-OZ lamps are 60 W lamps with 230 V power supply and equipped with:
- timer (can be switched on for 15, 30 or 60 minutes of continuous operation)
- remote control
- light bulb emitting radiation with a length of 185 nm (UV-V) or 253.7 nm (UV-C)
185 nm radiation produces ozone. The rays falling directly on the exposed surface cause it to be disinfected, while the ozone generated by the action of these waves destroys pathogens in hidden places that are not directly exposed. This also increases the effectiveness of the lamp disinfection and enables odors to be neutralized.
After disinfection with the PRIMAC UV-01-OZ lamp, room ventilation is essential.
RECOMMENDATIONS FOR USERS 60 WATT LAMPS |
Room area 3m high | Recommended disinfection time | Ventilation time (Series type -OZ) |
~ 10 m2 | 15 minutes | 30 minutes |
~ 20 m2 | 15 minutes | 30 minutes |
~ 40 m2 | 30 minutes | 40 minutes |
~ 60 m2 | 60 minutes | 40 minutes |