PRIMAC UV-03 lamp and PRIMAC UV-03-OZ lamp

PRIMAC UV-03 and UV-03-OZ lamps are 38 W lamps with a 230 V power supply, equipped with:

  • timer (can be switched on for 15, 30 or 60 minutes of continuous operation)
  • motion sensor (5 m range)
  • light bulb emitting radiation with a length of 185 nm (UV-V) or 253.7 nm (UV-C)

Thanks to the built-in motion sensor, the device can be conveniently used in rooms that people and animals can enter.

185 nm radiation produces ozone. The rays falling directly on the exposed surface cause it to be disinfected, while the ozone generated by the action of these waves destroys pathogens in hidden places that are not directly exposed. This also increases the effectiveness of the lamp disinfection and enables odours to be neutralized.

Room ventilation is essential after disinfection with the PRIMAC UV-03-OZ lamp.

RECOMMENDATIONS FOR  USERS
38 W LAMPS


room size 3m high

recommended disinfection time

recommended disinfection time
series–OZ)

~ 10 m2

15 minutes

30 minutes

~ 20 m2

30 minutes

30 minutes

~ 40 m2

60 minutes

40 minutes

Suitable e.g. to the:

  • hospitals, medical and dental practices, prosthetic laboratories, treatment and rehabilitation rooms, waiting rooms and pharmacies
  • beauty salons, nail salons
  • schools and kindergartens
  • fitness rooms, swimming pools and their changing rooms
  • items in the home; at work, such as the surfaces of chairs, laboratory tables, workstations, cupboards, furniture, carpets; also bags, bedding, plush toys, etc.
  • protection tools
  • planes, trains, buses

specification

  • dimensions: 186 x 186 x 420 mm
  • weight: 0.56 kg
  • range of UV-C radiation: 360°
  • operating modes: 15, 30 and 60 minutes
  • life span of the light bulb: up to 9000 hours

Confirmed with certificates:

  • directive 2014/35 / EU of the European Parliament and of the Council
  • directive 2014/30 / EU of the European Parliament and of the Council
  • standard EN 60598 2-4: 2018,
  • standard EN 60598 1: 2015 + A1: 2018
  • standard EN 55015: 2013 + A1: 2015,
  • standard EN 61547: 2009
  • standard EN 61000-3-2: 2014
  • standard EN 61000-3-3: 2013
  •  

Would you like to find out more or work with us?

  • The presence of living beings must be excluded while the UV lamp is in operation.
  • It is forbidden to be present during the anti-virus to avoid injuries caused by direct UV rays on the eyes and skin.
  • Personnel in the presence of ultraviolet radiation should wear protective clothing and eye protection.
  • During use, the surface of the UV lamp should be kept clean (it can be wiped with a gauze soaked in alcohol before switching on).
  • The disinfected surface should be exposed directly to ultraviolet light.
  • Ventilation is required after disinfection.
  • Ultraviolet rays can destroy a wide variety of microorganisms, including bacteria, spores, viruses, fungi, and other microorganisms.
  • Water and air can be disinfected with UV radiation.